Prescriptive roof consisting of the rafters a ridge board ceiling joists and collar ties.
Roof wall connection detail no overhead.
Detail title thrust restraint for fans december 2008 sd230541 02 dwg none.
For alternate 24 inch spacing of floor wall and roof fram ing where floor and roof trusses are used and accommodates 24 inch spacing of studs where wind loads.
The function of each component is.
Hand driven and pneumatic fasteners were included in the test program.
It is also used when the wall below provides a ledge with sufficient bearing area for the roof to bear on directly.
Drawings below are generic details to show design intent only.
Pocket connection a pocket connection consists of framing the floor or roof system into a void in the masonry wall.
The direct bearing connection is the simplest and most common connection in the home building industry.
Sip 122 beveled wall panelsip 122a beveled 2x blockingsip 122b beveled wedge blockingsip 122c gable endsip 122d plumb eave beveled wedge blockingsip 125 ceiling panel and trusssip 125a ceiling panels and raftersip 121d sip roof and wood ledgersip 121e sip roof and steel angle ledgersip 124 truss bearing on wall panelsip 124a truss bearing on wall panel.
The drawings will help you gain a better understanding of engineered system design options but these.
The tables below contain downloadable standard design detail drawings for typical unistrut applications medical supports rooftop walkways and ceiling grid systems.
This detail is used when masonry continues above either as part of the wall or as a parapet the connection location and eccentricity is to be minimized.
This detail for cmu installation only.
Flexible connection equipment vaned elbow provide all square or.
Where required by this section blocking between rafters or roof trusses shall be attached to top plates of braced wall panels and to rafters and roof trusses in accordance with table r602 3 1 a continuous band rim or header joist or roof truss.
X 5 8 bolt brass alum.
A direct bearing connection is used in instances where the wall below does not continue beyond the roof level i e no parapet.
Top plates of exterior braced wall panels shall be attached to rafters or roof trusses above in accordance with table r602 3 1 and this section.
Downspout strap detail 1 4 dia.
In a rafter roof all of these components are required to provide a stable roof.
Detail for attachment to metal panel siding or fascia.
Performance of conventional roof systems and components including ceiling joist to rafter connections and roof framing to wall connections.